Electrochemical
CLASSIC
FUTURA
FROST
Electromechanical
STAR VARIO
STAR CONTROL
PRO
PRO MP-6
ECOSY

|
perma CLASSIC

Installation
•
•
-
When
the activator becomes hand tight, take a screw driver and insert it through
the top ring of the activator (fig.1).
PERMA Classic activators are recognized by the Black O-ring seal and
Futura activators by their Pink O-ring seal.
Continue to tighten until the O-ring breaks off (fig. 2).
DO NOT break ring off by hand.
This could jeopardize the activation of the PERMA.
To insure the activation pellet has fallen from the activator into the
bladder that starts the chemical dispensing reaction, simply shake the PERMA
to hear the pellet rattle inside.
••
••
•
•
•
-
•Typically
most bearing lubrication ports are 1/8” or 1/4”.
The PERMA thread is 1/4” MNPT. If
the grease inlet is 1/8”, you will need a 1/4” F x 1/8” M adapter (part
# B100; fig. 3). If your
inlet is 1/4”, you can mount direct. Either
way, screw the PERMA into the fitting or bearing hand tight only.
•
•
•
•
-
Make
sure pipe or tubing is pre-filled with the same or compatible lubricant.
1-month (6 feet), 3-month (4 feet), 6-month (2 feet),
12-month (1 foot)
•