Technical data
|
FROST
|
|
Housing design
|
Metal with plastic cap
|
|
Drive
|
Electrochemical
|
|
Discharge period
|
1 to 26 weeks (with black activator screw)
|
|
Lubricant volume
|
120cc (4.2 oz)
|
|
Ambient temperature
|
-25° to 10° C / -13° to 50° F
|
|
Pressure build-up
|
Max. 4 bar / 58 psi
|
|
Dimensions
|
70mm x 99mm |
|
By tightening the activating screw the gas generator drops into the electrolyte fluid where it starts an electrochemical reaction that builds up pressure (up to 4 bar / 58 psi) and causes the piston to move forward. The lubricant is continuously injected into the lubrication point. The transparent casing permits easy monitoring of the amount of lubricant discharged. The lubrication period is determined by color activator screws (1, 3, or 6 months).
|
|
Discharge periods FROST
|
Discharge period (days)
|
|
Temp. average: -13° F
|
200
|
300
|
|
Temp. average: 5° F
|
100
|
150
|
|
Temp. average: 23° F
|
35
|
70
|
|
Temp. average: 41° F
|
12
|
32
|
|
Activating screw
|
black
|
brown
|
|
|
|
|